Transformer Marshalling Box Wiring Diagram

Big Banner

New Transformer Marshalling Box Wiring Diagram Marshalling Cabinets Definition | Www.Stkittsvilla.Com

New Transformer Marshalling Box Wiring Diagram Marshalling Cabinets Definition | Www.Stkittsvilla.Com

New transformer marshalling box wiring diagram - Auxiliary electricity deliver :. 110v/250v ac /- 10 frequency : ........................ 50hz electricity consumption: ....... 15va pt supply: ........................... 110vac time postpone adjustment : 10 to a hundred secs operatiing temperature : max. Fifty five deg c parallel operation :............ Model se: n/a ............................................... Model sag: 2 to five length: ...................................... 96mm x 96mm x120mm (se) ............................................... 230mm x 110mm x 100mm ............................................... (Sag) weight: ................................ 1 kg approx. (Se) ............................................... 4 kg approx. (Sag). Over voltage/underneath voltage safety: the avr has built in characteristic for protection towards uv/ov from pt. An aux. Relay is energized to perform an hooter. The uv and ov kingdom is proven on the liquid crystal display. You may also set the avr to get an sms to your cellular cellphone in case of ov/uv. Time put off: the have an effect on in alternate in voltage takes area most effective after the time delay (td) has elapsed as set by using the user. In different phrases the relay will ship command to the motor only after the time put off has elapsed. That is required to keep away from the motor start/stop on common voltage fluctuations. This put off time can be set from five to 125 seconds. Line drop compensator (ldc): this refers back to the drop in line voltage from producing quit to transformer number one. The ldc allows the avr to compensate this drop. The feature is brought on request on charge-in a position basis. Manipulate failure relay (cfr): if the oltc/avr malfuctions due to any purpose for sure preset time (say 10 minutes) then the cf relay will get energised and activated. An alarm may be related with this relay contacts. Once the controls resume the regular capabilities, the relay receives de-energized setting the alarm off. All this will be seen on the lcd. You could also set the avr to get an sms on your cellular telephone in case of control failure of the oltc avr. Auxiliary fail relay (afr): in case auxiliary supply to avr fails (from pt), the af relay receives activated. You can also set the avr to get an sms to your cellular phone in case of auxiliary deliver faiure. Tap function indicator (tpi): this feature is used to suggest the tap role. The faucet function is displayed on the lcd. You could get faucet postion to your cell cellphone additionally (on request). Oltc avr parallel operation: the oltc avr module has (elective) the supply to perform a couple of transformers in parallel. One transformer is taken because the grasp and the final as the followers so that they follow the grasp's lv voltage set values. Oltc avr on scada: oltc avr version sag-e44 may be monitored and manage through a wi-fi scada utility from any where in the world. You may display the whole parameters of a transformer like electric parameters, winding temperature (sensor required), oil temperature (sensor required), oil degree (sensor required), buclotz relay popularity. Oil leakage (sensor required).

Se även : Top Kenwood Kgc 6042A Wiring Diagram Kenwood Ddx470 Wiring Diagram Gooddy Org At - Autoctono.Me

The idea below may be something you are also looking for: